Skip to content
Guardian Structural Technologies

R-value and U-factor: which number to use

R-value measures resistance to heat flow and is reported for materials and assemblies. U-factor measures the rate of heat flow and is what codes use for windows and whole assemblies. They are reciprocals, and mixing them up is a common specification error.

The two numbers

R-value is thermal resistance: higher is better. U-factor is thermal transmittance: lower is better. For a simple assembly U equals one divided by R.

Insulation products are sold in R. Windows are specified in U. Whole assemblies appear in the codes both ways, which is why a specification can contain both and still be consistent.

Published thermal resistance by panel and thickness Guardian publishes each panel at two mean temperatures. A 12 inch roof panel is R-50 at 40 degrees Fahrenheit and R-46 at 75. A 9 and a quarter inch wall panel is R-38 and R-35. Roof 12 in R-50 Wall 9¼ in R-38 Roof 8 in R-33 Wall 7¼ in R-30 Roof 6 in R-25 Wall 6 in R-25 at 40 °F at 75 °F
Source: 3-Part Specification 1.5 E.5 b. Insulation R-value changes with temperature, so a figure quoted without its mean temperature is incomplete.

Why an R-value needs a temperature

The thermal conductivity of insulation changes with temperature, so an R-value is only meaningful alongside the mean temperature it was measured at. Standard test methods report it that way; marketing rarely does.

A specification that publishes two temperatures is telling you something useful: which figure to feed an energy model for a heating climate and which for a cooling one.

What Guardian publishes

  • Guardian publishes each panel at two mean temperatures, 40 °F and 75 °F, rather than a single headline figure.

    Source · 3-Part Specification 1.5 E.5 b

  • Roof panels: 12 in R-50 at 40 °F and R-46 at 75 °F; 8 in R-33 and R-30; 6 in R-25 and R-23.

    Source · 3-Part Specification 1.5 E.5 b

Written by Data Subsystems, for Guardian Structural Technologies. Last updated .

Drafted from Guardian Structural product literature and published building-science sources. Awaiting Guardian technical review. Confirm any figure against the current product documents or ask us before you rely on it in a design.

Talk to us about your project

Tell us what you are building. We design and produce the envelope to your exact drawings, residential or commercial.

Contact us